MPI-II
Universal S7interface-cable +++ RS232/USB to PPI/MPI/PROFIBUS +++ For HMI-USB applications +++ Bus-status on display
PPI/MPI/Profibus up to 12Mbit/s
- Supplied driver TIC (Total Integrated Communication) (runs under Windows (any)) allows communication and configuration of the interface product
- Function with TIA-Portal and Simatic-Manager, also with WinCC and Comfort Panel
- TIC-(Totally Integrated Communication)-driver for Step7/TIA-Portal for Windows (any) 32/64 Bit:
TIC firmware / configuration-tool / Step7-/TIA-driver
- Automatic protocol- and baudrate-detection (depends on the used product from 9K6 to 12M)
more...
variants:
ARTNR: 9352
MPI-II - Interfacecable 3m
359,00 € plus VAT. and shipping
ARTNR: 9352
MPI-II - Interfacecable 3m
EAN number: | 4260363240932 | |
HS-code: | 85444290 | |
Weight: | 0.3 kg |
S7
PPI-Bus | |||||||||
PPI 9.6 KBit/s - 19.2 KBit/s |
x
|
x
|
x
|
x
|
x
|
x
|
x
|
x
|
x
|
Multimaster 9.6 KBit/s - 187.5 KBit/s |
x
|
x
|
x
|
x
|
x
|
x
|
x
|
x
|
|
MPI-Bus | |||||||||
19.2 KBit/s |
x
|
x
|
x
|
x
|
x
|
x
|
x
|
x
|
x
|
187.5 KBit/s |
x
|
x
|
x
|
x
|
x
|
x
|
x
|
x
|
x
|
1.5 MBit/s |
x
|
x
|
x
|
x
|
x
|
x
|
x
|
x
|
|
Profibus | |||||||||
9.6 KBit/s |
x
|
x
|
x
|
x
|
x
|
x
|
x
|
x
|
|
19.2 KBit/s |
x
|
x
|
x
|
x
|
x
|
x
|
x
|
x
|
x
|
45.45 KBit/s |
x
|
x
|
x
|
x
|
x
|
x
|
x
|
x
|
|
93.75 KBit/s |
x
|
x
|
x
|
x
|
x
|
x
|
x
|
x
|
|
187.5 KBit/s |
x
|
x
|
x
|
x
|
x
|
x
|
x
|
x
|
x
|
500 KBit/s |
x
|
x
|
x
|
x
|
x
|
x
|
x
|
x
|
|
1.5 MBit/s |
x
|
x
|
x
|
x
|
x
|
x
|
x
|
x
|
|
3.0 MBit/s |
x
|
x
|
x
|
x
|
x
|
x
|
x
|
x
|
|
6.0 MBit/s |
x
|
x
|
x
|
x
|
x
|
x
|
x
|
x
|
|
12.0 MBit/s |
x
|
x
|
x
|
x
|
x
|
x
|
x
|
x
|
|
Profibus-profile | |||||||||
DP |
x(12)
|
x
|
x
|
x
|
x
|
x
|
x
|
x
|
x
|
standard |
x(12)
|
x
|
x
|
x
|
x
|
x
|
x
|
x
|
x
|
universal(DP/FMS) |
x
|
x
|
x
|
x
|
x
|
x
|
x
|
x
|
|
RS 232 | |||||||||
9.6 KBit/s |
x(19)
|
x(19)
|
|||||||
19.2 KBit/s |
x
|
x
|
|||||||
38.4 KBit/s |
x
|
x
|
|||||||
57.6 KBit/s |
x(9)
|
x(9)
|
|||||||
115.2 KBit/s |
x(9)
|
x(9)
|
|||||||
USB | |||||||||
USB 1.1 (6) |
x(1)
|
x
|
x(2)
|
||||||
LAN | |||||||||
10/100BaseTx |
x(7)
|
x
|
x
|
x
|
x
|
||||
WIFI | |||||||||
2.4 GHz |
x
|
||||||||
TeleService operation | |||||||||
with S7-300/400 |
x(14)(18)
|
x(14)(18)
|
|||||||
baud rates at TS-operation directly at the PC | |||||||||
9.6 KBit/s |
x
|
x
|
|||||||
19.2 KBit/s |
x
|
x
|
|||||||
38.4 KBit/s |
x(8)
|
x(8)
|
|||||||
57.6 KBit/s |
x(8)
|
x(8)
|
|||||||
baud rates at TS-operation directly with a modem | |||||||||
9.6 KBit/s |
x
|
x
|
|||||||
19.2 KBit/s |
x
|
x
|
|||||||
38.4 KBit/s |
x
|
x
|
|||||||
57.6 KBit/s |
x
|
x
|
|||||||
115.2 KBit/s |
x
|
x
|
|||||||
HMI | |||||||||
9.6 KBit/s |
x
|
x
|
x(13)
|
x(13)
|
x(13)
|
x(13)
|
x(13)
|
x(13)
|
x(13)
|
19.2 KBit/s |
x
|
x
|
x(13)
|
x(13)
|
x(13)
|
x(13)
|
x(13)
|
x(13)
|
x(13)
|
38.4 KBit/s |
x
|
x
|
x(13)
|
x(13)
|
x(13)
|
x(13)
|
x(13)
|
x(13)
|
x(13)
|
57.6 KBit/s |
x
|
x
|
x(13)
|
x(13)
|
x(13)
|
x(13)
|
x(13)
|
x(13)
|
x(13)
|
115.2 KBit/s |
x
|
x
|
x(13)
|
x(13)
|
x(13)
|
x(13)
|
x(13)
|
x(13)
|
x(13)
|
update | |||||||||
firmware-update |
x(10)
|
x(10)
|
x(15)
|
x(15)
|
x(15)
|
x(15)
|
x(15)
|
x(15)
|
x(15)
|
input/online help | |||||||||
keypad |
x
|
x
|
x
|
x(21)
|
x(21)
|
x(21)
|
x(21)
|
||
display |
x
|
x
|
x
|
x
|
x(21)
|
x(21)
|
x(21)
|
x(21)
|
|
PD connections (maximum) | |||||||||
PLCVCOM |
1
|
1
|
1
|
1
|
1
|
1
|
1
|
1
|
|
RFC1006 |
8
|
8
|
32
|
32
|
32
|
||||
AG connections (maximum) | |||||||||
passive subscriber |
1
|
15
|
15
|
15
|
15
|
15
|
15
|
15
|
15
|
active subscriber |
126
|
126
|
126
|
126
|
126
|
126
|
126
|
126
|
126
|
more functions | |||||||||
integrated PLC-firewall |
|
|
x
|
x
|
x
|
||||
display diagnostic-buffer in the webbrowser |
|
|
x
|
x
|
x
|
||||
webserver for configuration |
x
|
x
|
x
|
x
|
x
|
||||
Remote access over existing VPN-channel |
x
|
x
|
x
|
x
|
x
|
||||
Access via existing WLAN-channel |
x
|
x
|
x
|
x
|
x
|
||||
status/control variable |
x
|
x
|
x
|
x
|
x
|
||||
S7 on S7/S5 DB exchange |
x
|
x
|
x
|
x
|
x
|
||||
S5 on MPI DB exchange |
only as S5toMPI
|
||||||||
S7 on MPI (Send/Fetch) |
x
|
x
|
x
|
x
|
x
|
||||
Profinet Gateway |
x
|
x
|
x
|
x
|
x
|
||||
Time in PLC from NTP-server |
x
|
x
|
x
|
x
|
x
|
||||
galvanic separation | |||||||||
to the bus (screen connected through) |
1KV
|
1KV
|
1KV
|
1,5KV
|
1KV
|
1,5KV
|
1,5KV
|
1,5KV
|
1,5KV
|
mounting | |||||||||
wall monuting (with opt. wall mounting-set) |
x
|
x
|
x
|
x
|
|||||
upgrading with | |||||||||
CheapConn+cable |
x
|
x
|
x
|
x
|
|||||
supports | |||||||||
WIN 98 |
x
|
x(3)
|
x
|
x
|
x
|
x
|
x
|
||
WIN 98 SE |
x
|
x
|
x
|
x
|
x
|
x
|
x
|
x
|
x
|
WIN ME |
x
|
x
|
x
|
x
|
x
|
x
|
x
|
x
|
x
|
WIN NT |
x
|
x(5)
|
x(5)
|
x
|
x(5)
|
||||
WIN 2000 |
x
|
x
|
x
|
x
|
x
|
x
|
x
|
x
|
x
|
WIN XP Home (4) |
x
|
x
|
x
|
x
|
x
|
x
|
x
|
x
|
x
|
WIN XP Professional |
x
|
x
|
x
|
x
|
x
|
x
|
x
|
x
|
x
|
Vista(32bit) |
x
|
x
|
x
|
x
|
x
|
x
|
x
|
x
|
x
|
Win7(32bit) |
x
|
x
|
x
|
x
|
x
|
x
|
x
|
x
|
x
|
Win7(64bit) |
(22)
|
x(23)
|
x(20)
|
x(20)
|
x(20)
|
x(20)
|
x(20)
|
x(20)
|
x(20)
|
Win8/8.1 |
(22)
|
x(23)
|
x(20)
|
x(20)
|
x(20)
|
x(20)
|
x(20)
|
x(20)
|
x(20)
|
Win10 |
(22)
|
x(23)
|
x(20)
|
x(20)
|
x(20)
|
x(20)
|
x(20)
|
x(20)
|
x(20)
|
Win11 |
(22)
|
x(23)
|
x(20)
|
x(20)
|
x(20)
|
x(20)
|
x(20)
|
x(20)
|
x(20)
|
(1) just with USB-cable plug <-> plug, type A <-> A, item number: 9352.1 (2) just with USB-cable plug <-> plug, type A <-> mini B, item number: 9352.3 (3) only serial communication (4) Siemens Step7 V5.2 and higher dont run with this operationing system (5) USB-communication is only possible with the special driver for Win NT (6) USB 2.0 is backward compatible to 1.1 (7) Cable is designed for direct connection to PC network card socket. It can also be a hub / switch with uplink port or operated at a hub / switch with automatic detection of assignement and adaptation (8) only in combination with the MPI-Speed-driver („continously-active“) (9) Siemens Step7 supports these baud rates only with the MPI-Speed-Utility (10) Update directly with PC or via Tele-Network if the cable is connected to a device of the Tele-Network-family (Tele-Link, Tele-Book or Tele-Professional) (11) only in the mode: MultiMaster-Mode (12) up to a maximum baud rate of 187.5 KBit/s (13) In this transmission, the baud rate is irrelevant, because it communicates via a virtual COM-port. (14) with the use of the TS-adapter / item number: 9350.TS (15) Update directly with PC and TIC-driver (18) Operation requires Step 7 with additional software Tele-Service (TS) from Siemens (19) only at PPI-communication possible (20) Only with TIC-driver (21) with integrated webserver possible (22) No support of Siemens Step7-software possible (23) Only with USB and with TIC-driver |
- Supplied driver TIC (Total Integrated Communication) (runs under Windows (any)) allows communication and configuration of the interface product
- Function with TIA-Portal and Simatic-Manager, also with WinCC and Comfort Panel
- TIC-(Totally Integrated Communication)-driver for Step7/TIA-Portal for Windows (any) 32/64 Bit:
TIC firmware / configuration-tool / Step7-/TIA-driver
- Automatic protocol- and baudrate-detection (depends on the used product from 9K6 to 12M)
- Connects only to the bus when it is requested by PG
- Firmwareupdate via internet for free
- PPI-adapter for S7-200
- MPI/Profibus-adapter for S7-300 + 400
- CE/EMC compliant construction
- All intelligent MPI-interface-products including a free OPC-server-DA-license "OPC-Manager lite" [limited to 100 items]
- All products, including the examples and demo-version of communication-driver as download on the product-site
- DPV1-master of class 2 and supports all functions that a PG supports:
- Diagnosis, configuration and programming of controllers (via software such as Simatic-Manager, TIA-Portal)
- Diagnosis and configuration of DP-slaves (via software such as Starter)
- Integrated display for diagnostic-output
- Power supply from the S7-PLC or external
- Applicable as TS/HMI adapter
- USB-connector
- Double-sided connected cable
Programming S7-PLC/-modules via RS232/USB
PLC-programming/-communication from the PC "serial" or via "USB" from S7-200/300/400 or modules such as Sinamix, Sinumerik, MicroMaster, drives, converters.
PPI up to 187.5 Kbit (PPI + PPI advanced), MPI/Profibus up to 12 Mbit. Compatible with the Siemens driver "PC-adapter", communication only with 64-bit operating-systems via USB and TIC-driver (limitation of serial communication from Siemens to 32-bit operating-systems).
PPI up to 187.5 Kbit (PPI + PPI advanced), MPI/Profibus up to 12 Mbit. Compatible with the Siemens driver "PC-adapter", communication only with 64-bit operating-systems via USB and TIC-driver (limitation of serial communication from Siemens to 32-bit operating-systems).
Remote maintenance with TS-software without original TS-adaptor
You have to reach urgend your PLC via remote maintenance and have no TS-adaptor in your company? No problem, configure with the MPI-Kabelmanager your S7-interface-cable MPI-II-Kabel the mode "TS"
for "remote maintenance", connect this cable with the TS-Adapter (article number 9350-TS) with a standard modem and send it all to your client. Now you will be able to start the connection with
your TS-sofware and solve the problem. And this all without buying a original TS-adapter.
Visualisation of your S7-PLC via COM-Port
Your panel provides a serial port and no MPI/Profibus for connecting a S7-PLC. Connect the MPI-II-cable with it and you’re Online with your panel.
Coupling of S5-PLC with S7-PLC via PD-interfaces
S5 in the machine-park, conversion to S7 not profitable, central-control still requires production-data, who does not know this problem.
With "S5anMPI" you connect the S5-PLC with a standard interface-cable with the MPI/PROFIBUS of a S7-PLC. Loading handling-blocks in both PLCs, communication integrated and "S5anMPI" exchanges DB-content on request of the respective PLC. Configuration in the "S5anMPI" which PLC is active, also both PLCs active is possible.
Data-exchange without much effort and the S5-PLC continues in the S7-combination as usual and does not have to be replaced.
With "S5anMPI" you connect the S5-PLC with a standard interface-cable with the MPI/PROFIBUS of a S7-PLC. Loading handling-blocks in both PLCs, communication integrated and "S5anMPI" exchanges DB-content on request of the respective PLC. Configuration in the "S5anMPI" which PLC is active, also both PLCs active is possible.
Data-exchange without much effort and the S5-PLC continues in the S7-combination as usual and does not have to be replaced.
Supply voltage: | 24V DC +/- 20% |
Power consumption: | 2,5 watt |
Display: | double lined LCD-display |
Handling/Configuration: |
Kabelmanager-Software keypad on the back |
Interfaces: |
to the PLC:
PPI/MPI/Profibus interface: 9,6 KBd - 12 MBd
to the PD/PC:
RS232: 9,6 KBd - 115,2 KBdUSB 1.1 for cable type A <-> A |
Galvanic separation: | 1000V PPI/MPI/Profibus to the PC |
Operating temperature: | 0 - 55°C |
Case: | ABS-plastic case |
Dimensions: | 146 x 41 x 29 mm |
Scope of delivery: |
MPI-II-cable Power connector 2pins small |
All prices plus costs of delivery, shipping insurance and VAT.
accessories:
166,00 €
plus VAT. and shipping
plus VAT. and shipping
9391-USB
USB-powercable for 24V DC, max. 3W
USB-plug type A to 2 open braids 24V DC, maximum current: 125mA (for PC 100mA) length: 5m
USB-powercable for 24V DC, max. 3W
USB-plug type A to 2 open braids 24V DC, maximum current: 125mA (for PC 100mA) length: 5m
95,00 €
plus VAT. and shipping
plus VAT. and shipping
84,00 €
plus VAT. and shipping
plus VAT. and shipping
9391-HH
DIN-rail-holder for MPI/PPI
quick and easy assembling on the cap rail
DIN-rail-holder for MPI/PPI
quick and easy assembling on the cap rail
9350-WAND
Wall-mounting
for MPI/PPI + MPI-II + MPI-USB
Wall-mounting
for MPI/PPI + MPI-II + MPI-USB
4,00 €
plus VAT. and shipping
plus VAT. and shipping
48,00 €
plus VAT. and shipping
plus VAT. and shipping
9352-104-2
MPI-PC104-card 2 channel up to 12Mbaud Obsolete
equates to PC104-standard (90.2 x 95.9mm)
MPI-PC104-card 2 channel up to 12Mbaud Obsolete
equates to PC104-standard (90.2 x 95.9mm)
9352-104
MPI-PC104-card 1 channel up to 12Mbaud Obsolete
equates to PC104-standard (90.2 x 95.9mm)
MPI-PC104-card 1 channel up to 12Mbaud Obsolete
equates to PC104-standard (90.2 x 95.9mm)
59,00 €
plus VAT. and shipping
plus VAT. and shipping
6,00 €
plus VAT. and shipping
plus VAT. and shipping
37,00 €
plus VAT. and shipping
plus VAT. and shipping
11,00 €
plus VAT. and shipping
plus VAT. and shipping
32,00 €
plus VAT. and shipping
plus VAT. and shipping
9352-S7-BK
S7-bus-coupler
Disconnects all signals except differential bus lines Safety for all participants at VIPA 21x-2BM0x and 208-1DP0x
S7-bus-coupler
Disconnects all signals except differential bus lines Safety for all participants at VIPA 21x-2BM0x and 208-1DP0x
42,00 €
plus VAT. and shipping
plus VAT. and shipping
All prices plus costs of delivery, shipping insurance and VAT.
359,00 €
plus VAT. and shipping
plus VAT. and shipping
366,00 €
plus VAT. and shipping
plus VAT. and shipping
381,00 €
plus VAT. and shipping
plus VAT. and shipping
395,00 €
plus VAT. and shipping
plus VAT. and shipping
RS232
S5toMPI
Connects the S5-PLC with a S7-PLC
Connects the S5-PLC with a S7-PLC
MPI/PPI
S7-Interface cable for PPI, MPI, TS, HMI <=> RS232 applications
S7-Interface cable for PPI, MPI, TS, HMI <=> RS232 applications
All prices plus costs of delivery, shipping insurance and VAT.
559,00 €
plus VAT. and shipping
plus VAT. and shipping
32,00 €
plus VAT. and shipping
plus VAT. and shipping
9352-LANCON
S7-LAN connector for Siemens S7 PLC controller
Network-connection for the S7-200/300/400-PLC +++ S7-adapter PPI/MPI/PROFIBUS +++ Of developer and manufacturer +++ Smallest Ethernet-gateway S7 +++ Network for each S7-PLC +++ Fast commissioning +++ Replacement for CP343-1/443-1
S7-LAN connector for Siemens S7 PLC controller
Network-connection for the S7-200/300/400-PLC +++ S7-adapter PPI/MPI/PROFIBUS +++ Of developer and manufacturer +++ Smallest Ethernet-gateway S7 +++ Network for each S7-PLC +++ Fast commissioning +++ Replacement for CP343-1/443-1
423,00 €
plus VAT. and shipping
plus VAT. and shipping
9359-LAN
S5-LAN++
Industrial Ethernet <> S5 PD-interface (TTY) Including Gateway Plus and S7-TCP / IP functions
S5-LAN++
Industrial Ethernet <> S5 PD-interface (TTY) Including Gateway Plus and S7-TCP / IP functions
452,00 €
plus VAT. and shipping
plus VAT. and shipping
145,00 €
plus VAT. and shipping
plus VAT. and shipping